top of page

5100mz-Plus Vibrotome

  • Includes the Z-axis calibration unit (5100mz-Plus only)

  • Vibration frequency from 50 to 80 Hz

  • Adjustable amplitude from 0.5mm to 1.5mm

  • Fine control of the blade advance (min. 0.1 mm/sec)

  • Set start and finish position of blade travel

  • Remote controls allowing for sterile use in culture hood

  • Ice water bath easily removed for cleaning

  • Optional cold light and magnifier for clear observation

  • Optional Peltier cooled bath

Details

The 5100mz-Plus is perfect for those who need to keep slices viable for longer e.g. for electrophysiological field recordings. The user can calibrate the Z-axis deflection of the blade to 2 µm with the adjustable blade holder and “Opti-cal” Calibration device. Minimal Z-axis deflection reduces the “chatter” and minimises damage to the slice surface, leading to greater viability of the cells on the slice surface.

The New 5100mz series Vibrating Microtome shares the User interface with the premium 7000smz-2, placing a wide range of adjustable parameters at the user’s fingertips:

  • Vibration frequency from 50 to 80 Hz

  • Adjustable amplitude from 0.5mm to 1.5mm

  • Fine control of the blade advance (min. 0.1 mm/sec)

  • Set start and stop position of blade travel

  • Control box on umbilical cord ideal for operation in an isolated environment

 

Use in fully manual or the semi-automated "Slice window" mode which automatically remembers the start and finish position of the slice.

Further Information

Common Accessories

5100-1-3

5100-1-3

Integrally Mounted Cold Light Source and Magnifying Glass

A magnifying glass for general global slices offering approximately 1.5x magnification. Integral cold light powered directly via the Model 5100mz Vibrating Microtome

7550-1-C

7550-1-C

Ceramic Blades - 5 Pack

Specialised Ceramic blades for Campden Vibratomes. These blades are honed with a single bevel for superior slicing, particularly in tissue from older animals. Ceramic Microtome blades also need to be replaced less frequently than Stainless Steel Microtome blades; meaning less frequent z-axis recalibration is required.

7470-1-600.jpg

7470

Tissue Slice Recovery Chamber

The 7470 chamber was designed to hold and maintain tissue slices in six sub-chambers at physiological temperatures with an aeration supply to allow recovery from slicing as well as incubation during the experimental day (10-12 hrs).